Anatomic variation of the optic strut: classification schema, radiologic evaluation, and surgical relevance

视神经支架的解剖变异:分类方案、放射学评估和手术意义

阅读:1

Abstract

Objective Anatomic variability of the optic strut in location, orientation, and dimensions is relevant in approaching ophthalmic artery aneurysms and tumors of the anterior cavernous sinus, medial sphenoid wing, and optic canal. Methods In 84 dry human skulls, imaging studies were performed (64-slice computed tomography [CT] scanner, axial view, aligned with the zygomatic arch). Optic strut location related to the prechiasmatic sulcus was classified as presulcal, sulcal, postsulcal, and asymmetric. Morphometric analysis was performed. Results The optic strut was presulcal in 11.9% specimens (posteromedial margin bilaterally anterior to limbus sphenoidale), sulcal in 44% (posteromedial part adjacent to the sulcus's anterior two thirds bilaterally), postsulcal in 29.8% (posteromedial margin posterior to the sulcus's anterior two thirds), and asymmetric (left/right) in 14.3%. Optic strut length, width, and thickness measured 6.54 ± 1.69 mm, 4.23 ± 0.69 mm, and 3.01 ± 0.79 mm, respectively. Optic canal diameter was 5.14 ± 0.47 mm anteriorly and 4.79 ± 0.64 mm posteriorly. Angulation was flat (>45 degrees) in 13% or acute (<45 degrees) in 87% specimens. Conclusions Anatomical variations in the optic strut are significant in planning for anterior clinoidectomy and optic-canal decompression. Our optic strut classification considers these variations relative to the prechiasmatic sulcus on preoperative imaging.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。