Comparison of Common Methods for Precision Volume Measurement of Hematoma

血肿体积精确测量常用方法的比较

阅读:1

Abstract

PURPOSE: Our aim is to conduct analysis and comparison of some methods commonly used to measure the volume of hematoma, for example, slice method, voxelization method, and 3D-Slicer software method (projection method). METHOD: In order to validate the accuracy of the slice method, voxelization method, and 3D-Slicer method, these three methods were first applied to measure two known volumetric models, respectively. Then, a total of 198 patients diagnosed with spontaneous intracerebral hemorrhage (ICH) were recruited. The patients were split into 3 different groups based on the hematoma size: group 1: volume < 10 ml (n = 89), group 2: volume between 10 and 20 ml (n = 59), and group 3: volume > 20 ml (n = 50). And the shape of the hematoma was classed into regular (round to ellipsoid) with smooth margins (n = 76), irregular with frayed margins (n = 85), and multilobular (n = 37). The slice method, voxelization method, and 3D-Slicer method were adopted to measure the volume of hematoma, respectively, considering the nonclosed models and the models which may contain inaccurate normal information during CT scan. Moreover, the results were compared with the 3D-Slicer method for closed models. RESULTS: There was a significant estimation error (P < 0.05) using these three methods to calculate the volume of the closed hematoma model. The estimated hematoma volume was calculated to be 14.2086743 ± 0.900559087 ml, 14.2119130 ± 0.900851812 ml, and 14.2123825 ± 0.900835916 ml using slice method 1, slice method 2, and the voxelization method, respectively, compared to 14.212656 ± 0.900992371 ml using the 3D-Slicer method. The mean estimation error was -0.00398172 ml, -0.00074303 ml, and -0.00027354 ml caused by slice method 1, slice method 2, and voxelization method, respectively. There was a significant estimation error (P < 0.05), applying these three methods to calculate the volume of the nonclosed hematoma model. The estimated hematoma volume was calculated to be 14.1928246 ± 0.902210314 ml using the 3D-Slicer method. The mean estimation error was calculated to be -0.00402121 ml, -0.00078237 ml, -0.00031288 ml, and -0.01983136 ml using slice method 1, slice method 2, voxelization method, and 3D-Slicer method, respectively. CONCLUSIONS: The 3D-Slicer software method is considered as a stable and capable method of high precision for the calculation of a closed hematoma model with correct normal direction, while it would be inappropriate for the nonclosed model nor the model with incorrect normal direction. The slice method and voxelization method can be the supplement and improvement of the 3D-Slicer software method, for the purpose of achieving precision medicine.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。