Early Titration of Oxygen During Mechanical Ventilation Reduces Hyperoxemia in a Pilot, Feasibility, Randomized Control Trial for Automated Titration of Oxygen Levels

一项关于自动氧气水平滴定的试点可行性随机对照试验表明,在机械通气期间早期滴定氧气可降低高氧血症。

阅读:2

Abstract

Timely regulation of oxygen (Fio(2)) is essential to prevent hyperoxemia or episodic hypoxemia. Exposure to excessive Fio(2) is often noted early after onset of mechanical ventilation. In this pilot study, we examined the feasibility, safety, and efficacy of a clinical trial to prioritize Fio(2) titration with electronic alerts to respiratory therapists. STUDY DESIGN: Open-labeled, randomized control pilot trial. SETTING: Medical ICU. SUBJECTS: Adults requiring mechanical ventilation. INTERVENTIONS: Protocolized oxygen titration was initiated one hour after initiation of mechanical ventilation. When Spo(2) exceeded 92% while on Fio(2) ≥ 0.5, an electronic alert to respiratory therapists was triggered at 30-minute intervals. In the control arm, respiratory therapists titrated Fio(2) by standard physician's orders. MEASUREMENTS AND MAIN RESULTS: The primary end point was to determine if early Fio(2) titration based on automated alerts was feasible in terms of reducing hyperoxemia. Secondary analyses included the number and frequency of alerts, mechanical ventilation duration, and ICU length of stay. Among 135 randomized patients, 72 were assigned to the intervention arm and 63 to the control arm. A total 877 alerts were sent. Exposure to hyperoxemia was significantly reduced in the intervention group by a median of 7.5 hours (13.7 [interquartile range (IQR), 2.9-31.1] vs 21.2 [IQR, 10.9-64.4]; p < 0.0004). Maximal Fio(2) titration during the first quartile resulted in significant reduction in mechanical ventilation duration and ICU stay. Minor hypoxemic events (Spo(2) < 88%) represented 12% of alerts, 9% were transient and responded to a single Fio(2) increase, whereas 3% of alerts were associated with recurrent transient hypoxemia. CONCLUSIONS: Our pilot study indicates that early Fio(2) titration driven by automated alerts is feasible in the ICU, as reflected by a statistically significant reduction of hyperoxemia exposure, limited consequential hypoxemia, and reduced ICU resource utilization. The encouraging results of this pilot study need to be validated in a larger ICU cohort.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。