Comparison and combination of amide proton transfer magnetic resonance imaging and the apparent diffusion coefficient in differentiating the grades of prostate cancer

比较和结合酰胺质子转移磁共振成像和表观扩散系数在鉴别前列腺癌分级中的应用

阅读:1

Abstract

BACKGROUND: More effective risk stratification of prostate cancer (PCa) than that possible with current methods can reduce undertreatment and guard against overtreatment. The aim of this study is to validate the differences and combined effects of amide proton transfer (APT) imaging and apparent diffusion coefficient (ADC) in discriminating the PCa grade group (GG) ≤2 from GG ≥3 PCa. METHODS: This is an ongoing prospective study conducted in the radiology department of Nanxishan Hospital of Guangxi Zhuang Autonomous Region. Patients pathologically diagnosed with PCa were enrolled consecutively according to the eligibility criteria. A total of 180 patients (age range, 42-92 years) were included in this study. Using histopathology as the reference standard, we placed 71 cases in GG ≤2 (mean age 67.03±8.696 years) and 109 cases in GG ≥3 (age 69.60±9.638 years). Magnetic resonance imaging (MRI) parameters, including APT and ADC values, were analyzed using an independent samples t-test and binary logistic regression analysis stratified with GG. Receiver operating characteristic curve was used to analyze the diagnostic performance for different parameters distinguishing GG ≤2 and GG ≥3. RESULTS: APT [odds ratio (OR) for the transitional zone (TZ) PCa: 3.20, 95% CI: 1.14-8.98, P=0.02; OR for the peripheral zone (PZ) PCa: 86.32, 95% CI: 13.24-562.88, P=0.003] and ADC values (OR for TZ PCa: 89.79; 95% CI: 2.85-2,827.99, P=0.01; OR for PZ PCa: 39.92; 95% CI: 3.22-494.18, P=0.004) were independent predictors that differentiated the GG of patients. The sensitivity and specificity of the APT values were 61.1% and 81.0%, respectively, while the sensitivity and specificity of the ADC values were 83.3% and 61.9%, respectively. The optimal cutoff value of APT was 3.35% and which of ADC was 1.25×10(-3) mm(2)/s in TZ origin PCa. At the optimal cutoff values of 3.31% (APT) and 0.79×10(-3) mm(2)/s (ADC) in PZ PCa, the sensitivity and specificity of the APT values were 74.0% and 83.6%, respectively, while the sensitivity and specificity of the ADC values were 94.0% and 53.4%, respectively. The area under the curve of the combination of APT and ADC was significantly higher than either of APT or ADC alone in Delong test (TZ: P=0.002 and P=0.020; PZ: P=0.033 and P<0.001). CONCLUSIONS: APT and ADC have complementary effects on the sensitivity and specificity for identifying different PCa GGs. A combination model of APT and ADC could improve the diagnostic efficacy of PCa differentiation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。