Accumulation of iodine or other similar K-edge equivalent element within renal cysts mimics enhancing masses at single-phase dual-energy CT

肾囊肿内碘或其他类似K吸收边当量元素的积聚,在单期双能CT扫描中表现为类似增强肿块的影像。

阅读:1

Abstract

OBJECTIVE: To describe instances of iodine, or other element with similar K-edge to iodine, accumulating in benign renal cysts and simulating solid renal masses (SRM) at single-phase contrast-enhanced (CE) dual-energy CT (DECT). METHODS: During the course of routine clinical practice, instances of benign renal cysts (reference standard true non-contrast enhanced CT [NCCT] homogeneous attenuation <10 HU and not enhancing, or MRI) simulating SRM at follow-up single-phase CE-DECT due to iodine (or other element) accumulation were documented in two institutions over a 3-month observation period in 2021. RESULTS: Five Bosniak one renal cysts (12 ± 7 mm) in five patients changed nature on follow-up imaging simulating SRM at CE-DECT. At time of DECT, cyst attenuation on true NCCT (mean 91 ± 25 HU [Range 56-120]) was significantly higher compared to virtual NCCT (mean 11 ± 22 HU [-23-30], p = 0.003) and all five cysts showed internal iodine content on DECT iodine maps with concentration >1.9 mg ml(-1) (mean 8.2 ± 7.6 mg ml(-1) [2.8-20.9]). CONCLUSION: The accumulation of iodine, or other element with similar K-edge to iodine, in benign renal cysts could simulate enhancing renal masses at single-phase contrast-enhanced DECT.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。