Corrosion behavior of X80 pipeline steel local defect pits under static liquid film

X80管线钢局部缺陷坑在静态液膜下的腐蚀行为

阅读:1

Abstract

In this work, the corrosion electrochemical information under different thicknesses of liquid film was tested. The local corrosion development process of X80 steel under different thicknesses of liquid film was studied by combining the detection and analysis of scale and the matrix corrosion morphology. The corrosion was studied by EIS. The composition and microstructures of corrosion scale at different locations were detected by EDS and SEM, and the metal matrix was detected by 3D topography technology to analyze the local corrosion. The results show that a liquid film with a thickness greater than or equal to 1 mm has no effect on the mechanism of the corrosion process, but has a control effect on the corrosion rate and the time of each stage in corrosion. The corrosion process can be divided into two stages: in the early stage, the concentration of ions inside and outside ADP is the same, so the corrosion is uniform; in the later stage, due to the influence of CO(2) dissolution and mass transfer distance, the cathodic reaction is mainly outside ADP and the anodic reaction is mainly inside ADP. In addition, corrosion acidification occurs in ADP, which enhances the corrosion process in ADP.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。