Three-dimensional analysis of aligner gaps and thickness distributions, using hard x-ray tomography with micrometer resolution

利用微米级分辨率的硬X射线断层扫描技术,对矫正器间隙和厚度分布进行三维分析

阅读:1

Abstract

PURPOSE: The morphology of a polymer aligner, designed according to an orthodontic treatment plan, determines clinical outcomes. A fundamental element of orthodontic tooth movement with aligner treatment is the fit of the aligner's surface to the individual teeth. Gaps between the aligner and teeth do occur because current aligner fabrication is not capable of completely reproducing the complex anatomy of the individual denture. Our study aims at a quantitative three-dimensional assessment of the fit between optically transparent aligners placed on a polymeric model of the upper dental arch for two thermofoil thicknesses at preselected thermoforming temperatures. APPROACH: Using an intraoral scan of a subject's upper dental arch, eight models were printed using a stereolithographic system. A series of eight NaturAligners(®) was manufactured with a pressure molding process, using thermofoils with thicknesses of 550 and 750  μm and preselected process temperatures between 110°C and 210°C. These aligners placed on the corresponding models were imaged by an advanced micro computed tomography system. The aligners and the models were segmented to extract the gaps and aligners' local thicknesses as a function of the processing temperature for the two foil thicknesses. RESULTS: The results indicate that the aligners show a better fit when the foils are processed at higher temperatures. Nevertheless, processing temperatures can be kept below 150°C, as the gain becomes negligible. Thermal processing reduces the average thickness of the aligners to 60% with respect to the planar starting foil. These thickness distributions demonstrate that the aligners are generally thicker on the occlusal surfaces of molars and premolars but thinner around the incisors and buccal as well as on oral surfaces. CONCLUSIONS: Hard x-ray tomography with micrometer resolution is a powerful technique employed to localize the gaps between aligners and teeth, and it also enables film thickness measurements after thermoforming. The thicker film on the occlusal surfaces is most welcome because of aligner abrasion during wear. The NaturAligner(®) surfaces consist of a 25-μm -thin cellulose layer, and thus the microplastics released via abrasion of less than this thickness are expected to be substantially less critical than for other commercially available, optically transparent aligners.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。