Microstructural Effects in the Development of Near-Neutral pH Stress Corrosion Cracks in Pipelines

近中性pH条件下管道应力腐蚀裂纹发展过程中的微观结构效应

阅读:1

Abstract

The corrosion and stress corrosion cracking (SCC) behaviors of 20#, X60, and X80 pipeline steels in a near-neutral pH environment were investigated by means of electrochemical measurement, immersion test, and interrupted slow strain rate tensile (SSRT) test. The propensity for SCC, as indicated by the stress threshold value for crack initiation, was found to be dependent on the type of steel microstructure. Cracks were initiated in the high-strength steel X80 at a stress less than its yield strength, whereas in the other lower-grade steels, the initiation of cracks occurred after the yielding point. The threshold stress of SCC initiation in the near-neutral pH environment for 20#, X60, and X80 steels were 130.64% σ(ys), 106.79% σ(ys), and 86.92% σ(ys), respectively. The SCC of 20# and X60 were characterized by the formation of transgranular and intergranular cracks, while X80 steel was only by transgranular cracking. The occurrence of corrosion had a great effect on crack initiation and the growth at the later stage. The latter involved hydrogen effects. A correlation between SCC sensitivity and the yield strength of the steel has been identified.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。