Detection of colonic dysplasia in vivo using a targeted heptapeptide and confocal microendoscopy

利用靶向七肽和共聚焦显微内镜技术在体内检测结肠发育不良

阅读:1

Abstract

A combination of targeted probes and new imaging technologies provides a powerful set of tools with the potential to improve the early detection of cancer. To develop a probe for detecting colon cancer, we screened phage display peptide libraries against fresh human colonic adenomas for high-affinity ligands with preferential binding to premalignant tissue. We identified a specific heptapeptide sequence, VRPMPLQ, which we synthesized, conjugated with fluorescein and tested in patients undergoing colonoscopy. We imaged topically administered peptide using a fluorescence confocal microendoscope delivered through the instrument channel of a standard colonoscope. In vivo images were acquired at 12 frames per second with 50-microm working distance and 2.5-microm (transverse) and 20-microm (axial) resolution. The fluorescein-conjugated peptide bound more strongly to dysplastic colonocytes than to adjacent normal cells with 81% sensitivity and 82% specificity. This methodology represents a promising diagnostic imaging approach for the early detection of colorectal cancer and potentially of other epithelial malignancies.

特别声明