Impact of a system to assist in clinical decision-making in primary healthcare in Catalonia: prescription Self Audit

加泰罗尼亚初级医疗保健临床决策辅助系统的影响:处方自我审核

阅读:1

Abstract

BACKGROUND: In 2008, in the context of a complete computerisation of medical records, the Institut Català de la Salut (ICS, Catalan Health Institute) implemented a system in its electronic clinical workstation (ECW) to assist decision-making at the prescription level. This system is known as Self Audit, and it supports physicians in reviewing the medication of their patients. Self Audit provides lists of patients presenting medication-related problems (MRPs) that have potential for improvement, and provides therapeutic recommendations that are easy to apply from the system itself. The aim of this study was to analyse the main results derived from the use of Self Audit in primary care (PC) in Catalonia, and the effect of an incentive-based safety indicator on the results obtained. METHODS: A descriptive cross-sectional study was carried out to analyse variations in the MRPs detected by Self Audit during 2016, 2017, and 2018 in PC in Catalonia. The effect of a safety indicator on the results obtained was also studied. This safety indicator includes the most clinically relevant MRPs (i.e., therapeutic duplications, safety alerts from the Spanish Medicines Agency, and incidences of polymedication in patients over 65 years of age). Variation in the MRPs was measured using the differences between two evaluation points (initial and final). An MRP was considered resolved if the recommendation specified in the alert was followed. The prescriptions of 6411 PC doctors of the ICS who use the ECW and provide their services to 5.8 million Catalans through 288 PC teams were analysed. RESULTS: Analysis of the total safety-based MRPs detected by Self Audit gave overall resolutions from April to December of 9% (21,547) in 2016, 7% (15,924) in 2017, and 1% (2392) in 2018 out of the total number of MRPs recorded in April each year. Examination of the 3 types of MRPs with the highest clinical relevance that were linked to the safety indicator gave overall resolutions of 41% in 2016 (17,358), 20% in 2017 (7655), and 21% in 2018 (8135). CONCLUSIONS: The ICS Self Audit tool assists in reducing the number of safety-based MRPs in a systematic manner, and yields superior results for the MRPs linked to a safety indicator included in the incentives of PC physicians.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。