Innovative application of an implantable venous access system in the portal vein: technique, results and complications in three dogs

植入式静脉通路系统在门静脉中的创新应用:三只犬的技术、结果和并发症

阅读:2

Abstract

BACKGROUND: Vascular access port (VAP) systems are widely used in human medicine to provide long-term venous access. However, in veterinary medicine the use of VAP systems is not common practice and publications on their potential applications have been limited. A VAP system was used as part of an experimental study on liver regeneration and implanted in the canine portal vein to create direct access to the portal venous circulation of the liver. The aim of the present study is to describe the surgical technique, its use, and the complications of a VAP system in three research dogs. RESULTS: The VAP system was successfully used for the intraoperative measurement of portal blood pressure, the administration of cell suspensions, and the collection of portal venous blood samples. Long-term complications consisted of dislocation of the VAP system in one dog (2 months after implantation) and thrombus formation at the catheter tip in two dogs (3 months after implantation). Both complications prevented further use of the VAP but had no adverse clinical implications. CONCLUSIONS: This pilot study suggests that the VAP system is an effective and safe technique to obtain long term access to the portal venous system in dogs. However, complications with port detachment and thrombosis may limit long term use of VAPs in the portal system of dogs.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。