Effect of the Residual Errors on the Dose for Left-Sided Breast Cancer Radiotherapy After Translation Error Correction Based on CBCT

基于锥形束CT的平移误差校正后残余误差对左侧乳腺癌放射治疗剂量的影响

阅读:2

Abstract

ObjectiveThis study analyzed the dosimetric impact of residual errors (rotational and deformation errors) in left-sided breast cancer radiotherapy after cone-beam CT (CBCT)-based translational errors correction.MethodsTwenty patients treated with intensity-modulated radiotherapy (IMRT) were retrospectively analyzed. Virtual CT images were generated by deforming and registering CBCT images with planning CT images. The accumulated dose was calculated to assess residual errors effects on target and organs at risk (OARs). A phantom test was conducted to evaluate rotational errors impacts.ResultsResults showed significant dose differences: for 4005 cGy, D98 and D95 of the breast (PTV(b)) decreased, and mean dose, V30, and V20 of the left lung reduced; for 5000 cGy, D98 of the supraclavicular lymph nodes (PTV(sc)) and PTVb, D95 of PTV(b), and mean dose and V20 of the heart differed significantly. Phantom simulations revealed that pitch angles ≤-1.8° and roll/yaw angles >2° caused overdosing in the left lung and heart, with maximum dose differences of 31.89% (heart) and 19.19% (lung) for 4005 cGy, and 26.32% (heart) and 20.92% (PTV(sc)) for 5000 cGy.ConclusionResidual errors significantly affect dose distribution despite CBCT-based translational correction. Improved immobilization techniques or 6DOF couch correction are recommended to mitigate rotational errors.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。