Abstract

Introduction: Currently, the incidence of liver cancer is on the rise annually. Precise identification of liver tumors is crucial for clinicians to strategize the treatment and combat liver cancer. Thus far, liver tumor contours have been derived through labor-intensive and subjective manual labeling. Computers have gained widespread application in the realm of liver tumor segmentation. Nonetheless, liver tumor segmentation remains a formidable challenge owing to the diverse range of volumes, shapes, and image intensities encountered. Methods: In this article, we introduce an innovative solution called the attention connect network (AC-Net) designed for automated liver tumor segmentation. Building upon the U-shaped network architecture, our approach incorporates 2 critical attention modules: the axial attention module (AAM) and the vision transformer module (VTM), which replace conventional skip-connections to seamlessly integrate spatial features. The AAM facilitates feature fusion by computing axial attention across feature maps, while the VTM operates on the lowest resolution feature maps, employing multihead self-attention, and reshaping the output into a feature map for subsequent concatenation. Furthermore, we employ a specialized loss function tailored to our approach. Our methodology begins with pretraining AC-Net using the LiTS2017 dataset and subsequently fine-tunes it using computed tomography (CT) and magnetic resonance imaging (MRI) data sourced from Hubei Cancer Hospital. Results: The performance metrics for AC-Net on CT data are as follows: dice similarity coefficient (DSC) of 0.90, Jaccard coefficient (JC) of 0.82, recall of 0.92, average symmetric surface distance (ASSD) of 4.59, Hausdorff distance (HD) of 11.96, and precision of 0.89. For AC-Net on MRI data, the metrics are DSC of 0.80, JC of 0.70, recall of 0.82, ASSD of 7.58, HD of 30.26, and precision of 0.84. Conclusion: The comparative experiments highlight that AC-Net exhibits exceptional tumor recognition accuracy when tested on the Hubei Cancer Hospital dataset, demonstrating highly competitive performance for practical clinical applications. Furthermore, the ablation experiments provide conclusive evidence of the efficacy of each module proposed in this article. For those interested, the code for this research article can be accessed at the following GitHub repository: https://github.com/killian-zero/py_tumor-segmentation.git.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。