The Capabilities and Characteristics of Helical Tomotherapy and Co-Planar Dual Arcs Volumetric-Modulated arc Therapy Associated with Hippocampal Sparing During Prophylactic Cranial Irradiation

螺旋断层放射治疗和共面双弧容积调强弧形放射治疗在预防性颅脑照射中保护海马的能力和特点

阅读:1

Abstract

Objective: To investigate the features of helical tomotherapy and co-planar dual Arcs volumetric-modulated arc therapy during prophylactic cranial irradiation associated with bilateral hippocampal tissue sparing. Materials and methods: Helical tomotherapy and co-planar dual arcs volumetric-modulated arc therapy treatment plans were generated with a dose of 30 Gy/10 fractions in 16 patients treated with prophylactic cranial irradiation. The dose to the bilateral hippocampal tissues, organs at risk, and planning target volume were determined when the average dose of bilateral hippocampal tissues was reduced by approximately 4 Gy as an observation point. Changes in dosimetry when sparing the bilateral hippocampal tissues were determined for both modalities. Results: When bilateral hippocampal tissues were restricted to 8 Gy, D(40%mean-bilateral hippocampal tissues) = 7.64 ± 0.41 Gy in helical tomotherapy, while D(40%mean-bilateral hippocampal tissues) = 10.96 ± 0.38 Gy in co-planar dual arcs volumetric-modulated arc therapy volumetric-modulated arc therapy. Helical tomotherapy was associated with significantly lower doses to organs at risk, including D(mean-bilateral hippocampal tissues) (P = .03), D(98%-bilateral hippocampal tissues) (P = .01), D(2%-bilateral hippocampal tissues) (P = .01), D(mean-inner ear) (P = .02), D(mean-parotid glands) (P = .02), D(max-lens) (P = .02), and D(max-brainstem) (P = .02), but not D(max-optic nerves) (P = .87). Helical tomotherapy provided better target coverage, with lower average D(2%-PTV) (P = .02), higher average D(98%-PTV) (P = .02), and better conformal index (0.87 vs 0.84, P = .02) and homogeneity index (0.15 vs 0.21, P = .05). With smaller bilateral hippocampal tissues doses, the planning target volume dose changed across 3 dosimetry regions for both modalities; the plateau region (>20.0 Gy for helical tomotherapy versus >16.0 Gy for co-planar dual arcs volumetric-modulated arc therapy), gradient region (20.0-12.0 Gy vs 16.0-11.0 Gy), and falling region (<12.0 Gy vs <11.0 Gy). The average delivery duration of helical tomotherapy was almost 7.7 times longer than that of co-planar dual arcs volumetric-modulated arc therapy. Conclusions: Helical tomotherapy was better at sparing the bilateral hippocampal tissues and organs at risk and had better target coverage but a significantly longer treatment duration than co-planar dual arcs volumetric-modulated arc therapy. Further dose decreases in the bilateral hippocampal tissues would yield worse target dose coverage.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。