A giant bleb over a non-valved tube successfully treated with compression sutures

用压迫缝合术成功治疗了无瓣膜导管上的巨大水疱

阅读:3

Abstract

PURPOSE: To report a rare case of an anteriorly enlarged giant bleb following Ahmed ClearPath 350 glaucoma drainage device implantation, successfully treated with compression sutures. OBSERVATIONS: A 50-year-old man with a history of primary open angle glaucoma and multiple prior glaucoma procedures presented with a progressively enlarging inferonasal conjunctival bleb in the right eye, six months after Ahmed ClearPath 350 implantation. Examination revealed visual acuity (VA) of 20/40, intraocular pressure (IOP) of 6 mmHg, and a large, elevated, fluid-filled conjunctival bleb. While bleb formation is a desired outcome following glaucoma drainage device (GDD) implantation and trabeculectomy, the increasingly large size of this bleb caused discomfort, worsening vision, and difficulty closing the eye. Due to its rare nature, there was little consensus available regarding treatment. Compression sutures were placed in attempt to flatten the bleb. At one-week follow-up, vision and discomfort improved and slit-lamp examination revealed a markedly flatter bleb. Sutures were sequentially removed via slit-lamp during the one-month and two-month postoperative visits. At one-year follow-up, VA was 20/25, IOP was 6 mmHg, and slit lamp examination revealed a completely flattened inferonasal bleb. CONCLUSIONS AND IMPORTANCE: This case highlights a rare presentation of a giant inferonasal conjunctival bleb developing several months after Ahmed ClearPath 350 implantation. The successful use of compression sutures suggests they may be a viable treatment option for similar post-GDD implantation bleb complications.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。