PURPOSE: To report Anterior Segment Optical Coherence Tomography (ASOCT) characteristic and its usefulness in the case of Descemet's membrane (DM) anchoring caterpillar seta, highlighting the importance of vertical scans of ASOCT in detecting and delineating the deep seta and its anterior chamber (AC) penetration. OBSERVATION: A 30-year-old male patient presented with complaints of foreign body sensation and watering in the left eye after falling of an insect. Slit-lamp examination showed the presence of two caterpillar hairs, one embedded in the superficial conjunctiva and the second one embedded in the corneal stroma. Conjunctival hair was removed leading to the resolution of symptoms. ASOCT was done for deep corneal hair which showed DM breach and AC protrusion in volume vertical scans. ASOCT scan on follow-up visit showed migration of seta in AC. Deep seta being inert was not removed and the patient was closely followed. CONCLUSION: and IMPORTANCE: To the best of our knowledge, this is the first case reporting vertical scan imaging of caterpillar seta and showing AC migration of seta on ASOCT.