A modified surgical technique for Descemet's stripping automated endothelial keratoplasty (DSAEK) in altered or abnormal anatomy

针对解剖结构改变或异常的角膜,采用改良的Descemet膜剥离自动内皮角膜移植术(DSAEK)

阅读:1

Abstract

PURPOSE: This paper describes a modified technique for the Descemet's Stripping Automated Endothelial Keratopasty (DSAEK) surgery in eyes with abnormal or altered anatomy. Certain anatomic abnormalities increase the level of surgical complexity, and lead to increased risk of donor lenticule detachment. These challenges include aniridia, abnormal iris, aphakia and hypotony from previous vitrectomy. OBSERVATIONS: The Sheets glide was trimmed to 4mm in width and inserted into the clear-corneal wound. The "needle-push"/Fichman glide technique was used to insert the DSAEK donor graft. The modification of the technique involves maintaining the Sheets glide in the eye for the duration of the intraoperative air bubble. After confirming desired orientation of the graft, air was injected into the anterior chamber, creating a large air bubble between the graft and the Sheets glide. After 10 minutes, the Sheets glide was removed, and the main wound was closed. CONCLUSIONS AND IMPORTANCE: This technique overcomes the challenges of posterior air bubble migration and posterior dislocation of the donor lenticule in eyes with altered anatomy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。