[Evaluation of carotid atherosclerotic plaques by vascular plaque quantification (VPQ) technology of three-dimensional ultrasonography]

[利用三维超声血管斑块定量(VPQ)技术评估颈动脉粥样硬化斑块]

阅读:2

Abstract

OBJECTIVE: To analyze the feasibility of using vascular plaque quantification (VPQ) to evaluate carotid atherosclerotic plaques and to observe the effect of statins on carotid atherosclerotic plaques. METHODS: Patients with carotid plaques from January 2016 to September 2018 in Peking University First Hospital Neurology Department were recruited and underwent three-dimonsional ultrasound (3DUS). Their gray scale median (GSM) and other parameters of carotid plaques were measured with VPQ. The patients were divided into low GSM group (GSM < 40) and high GSM group (GSM≥40). The clinical characteristics and plaque characteristics of the patients in the two groups were compared to analyze the stability of plaques. According to whether taking statins or not, the patients were further divided into statin group and non-statin group, plaque GSM and other parameters of their carotid plaques were measured and the changes of carotid plaques at the end of 3 months and 2 years were observed. RESULTS: A total of 120 patients were enrolled, including 79 males and 41 females, with an average age of (65.39±9.11) years. The patients were divided into low GSM group (31 cases) (GSM < 40) and high GSM group (89 cases) (GSM≥40). The stenosis of the lumen in the low GSM group was more severe (the area stenosis rate was 41.32%±21.37% vs. 29.79%±17.16%, P < 0.05). The nor-malized wall index (NWI) of plaque in low GSM group was significantly higher than that in high GSM group (0.61 ±0.14 vs. 0.52±0.12, P < 0.01). A total of 77 patients, including 51 males and 26 females, aged (64.96±9.58) years, were enrolled to observe the statin effects on carotid plaque. They were divided into statin group (n=56) and non-statin group (n=21) according to whether taking statins or not. At the baseline and 3-month follow-up, there were no significant differences in carotid plaque volume, area, degree of luminal stenosis and GSM between the two groups (P>0.05). At the end of the 2-year follow-up, GSM increased in the statin group [median 10.00 (2.00, 28.00)] but decreased in the non-statin group [median -7.00 (-11.00, 5.50)], with a statistically significant difference between the two groups (P < 0.01). There was no significant increase in carotid plaque volume in the statin group, while there was a slight increase in the non-statin group, but there was no significant difference between the two groups [median increase in plaque volume was 0.00 (-30.00, 40.00) mm(3) in the statin group and 30.00 (10.00, 70.00) mm(3) in the non-statin group, P>0.05]. CONCLUSION: The VPQ technology of 3DUS can be used to evaluate carotid atherosclerotic plaques. Patients with low GSM (GSM < 40) have more severe vascular stenosis and higher normalized wall index. VPQ technology can also be used to observe the effect of statins on carotid plaque, the GSM of plaques increase in patients who are taking moderate-intensity statin treatment for two years.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。