Measuring eddy covariance fluxes of ozone with a slow-response analyser

使用慢响应分析仪测量臭氧涡流协方差通量

阅读:7
作者:Georg Wohlfahrt, Lukas Hörtnagl, Albin Hammerle, Martin Graus, Armin Hansel

Abstract

Ozone (O3) fluxes above a temperate mountain grassland were measured by means of the eddy covariance (EC) method using a slow-response O3 analyser. The resultant flux loss was corrected for by a series of transfer functions which model the various sources of high- and, in particular, low-pass filtering. The resulting correction factors varied on average between 1.7 and 3.5 during night and day time, respectively. A cospectral analysis confirmed the accuracy of this approach. O3 fluxes were characterised by a comparatively large random uncertainty, which during daytime typically amounted to 60 %. EC O3 fluxes were compared against O3 flux measurements made concurrently with the flux-gradient (FG) method. The two methods generally agreed well, except for a period between sun rise and early afternoon, when the FG method was suspected of being affected by the presence of photochemical sources/sinks. O3 flux magnitudes and deposition velocities determined with the EC method compared nicely with the available literature from grassland studies. We conclude that our understanding of the causes and consequences of various sources of flux loss (associated with any EC system) has sufficiently matured so that also less-than-ideal instrumentation may be used in EC flux applications, albeit at the cost of relatively large empirical corrections.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。