Target coverage of daily cone-beam computed tomography in breath-hold image-guided radiotherapy for gastric lymphoma

胃淋巴瘤屏气图像引导放射治疗中每日锥形束计算机断层扫描的目标覆盖率

阅读:1

Abstract

OBJECTIVES: We evaluated retrospectively the daily target coverage using cone-beam computed tomography (CBCT) in breath-hold image-guided radiotherapy (BH-IGRT) for gastric lymphoma. METHODS: BH-IGRT was performed using a prescribed dose of 30.6 Gy in 17 fractions for the whole stomach. We assessed the target coverage of the whole stomach on daily CBCT images [daily clinical target volume (CTV)], which was delineated individually by two observers. We evaluated V(95%) (percentage of volume receiving ≥95% of the prescribed dose) of daily CTV. RESULTS: In total, 102 fractions from 6 patients were assessed. The mean V(95%) of daily CTV was 97.2%, which was over 95%. In two of six patients, the V(95%) of daily CTV was over 95% for either observer in all fractions. One patient had significant interobserver variation (p = 0.013). In 95 fractions (93%), the V(95%) of daily CTV was over 95% for either observer. CONCLUSION: Daily target coverage for CTV in BH-IGRT for gastric lymphoma seems to be favorable, even when using CBCT. ADVANCES IN KNOWLEDGE: A previous study ascertained good daily target coverage in BH-IGRT for gastric lymphoma using in-room CT. Even when using CBCT in our study, daily target coverage for CTV in BH-IGRT for gastric lymphoma seems to be favorable.