Fixation of cancellous bone and physeal fractures in dogs and cats. A comparison of the use of self-reinforced biodegradable devices to the use of metallic devices and external fixations

犬猫松质骨和骨骺骨折的固定:自增强型可生物降解装置与金属装置和外固定装置的比较

阅读:1

Abstract

The use of self-reinforced biodegradable devices made of polyglycolide in the cancellous bone and physeal fractures of dogs and cats was compared to the use of metallic devices and external fixations on similar fractures. The series consisted of 64 dogs and 22 cats divided into 6 comparable groups. The patients in the 2 groups fixed with biodegradable devices started to use their operated limbs earlier than in the other groups. The same 2 groups also healed clinically (showed no lameness) earlier than the other groups. Radiographically there was no statistical difference between the 6 groups. On the basis of this study it may be concluded that the fixation with self-reinforced biodegradable devices is as suitable for the fixation of cancellous bone and physeal fractures of dogs and cats as the fixation with metallic devices or external fixation. This biodegradable technique has additional benefits allowing the patients to feel less pain in their operated limbs and making secondary operations to remove the devices unnecessary.