Parapedicular vertebral augmentation with polymethylmetacrylate for pedicle screw loosening

采用聚甲基丙烯酸甲酯进行椎弓根旁椎体增强术治疗椎弓根螺钉松动

阅读:1

Abstract

A 71-year-old man who had a L1/S1 posterior fusion revision surgery complained of increasing back pain 5 weeks after the open surgical procedure. The pain was initially estimated at 9/10 on the visual analog scale (VAS) and thought to be related to a right-sided L2 screw loosening. A right parapedicular vertebroplasty was performed and polymethylmethacrylate cement was instilled around the right pedicle screw, filling the anterior two-thirds of the vertebral body. On postvertebroplasty day 1, the patient had significant improvement in his low back pain. The pain further decreased at 1 and 3 months after the intervention (2/10 on the VAS). Vertebroplasty is a minimally invasive, accessible, effective, and long lasting treatment for compression fractures. We believe that this technique could also be indicated to treat pain related to low grade screw loosening in properly selected patients.