Cerebral blood volume mapping with ferumoxytol in dynamic susceptibility contrast perfusion MRI: Comparison to standard of care

利用铁氧乙醇进行动态磁敏感对比灌注磁共振成像脑血容量测定:与标准治疗的比较

阅读:2

Abstract

BACKGROUND: Cerebral blood volume (CBV) mapping with a dynamic susceptibility contrast (DSC) perfusion technique has become a clinical tool in diagnosing and follow-up of brain tumors. Ferumoxytol, a long-circulating iron oxide nanoparticle, has been tested for CBV mapping, but the optimal dose has not been established. PURPOSE: To compare ferumoxytol DSC of two different doses to standard of care gadoteridol by analyzing time-intensity curves and CBV maps in normal-appearing brain regions. STUDY TYPE: Retrospective. SUBJECTS: Fifty-four patients with various brain disorders. FIELD STRENGTH/SEQUENCE: 3T MRI. DSC-MRI was performed with 0.1 mmol/kg gadoteridol and 1 day later with ferumoxytol in doses of 1 or 2 mg/kg. ASSESSMENT: Signal changes during first pass, relative CBV (rCBV) in normal-appearing thalamus, putamen, and globus pallidus, and contrast-to-noise ratio (CNR) of the CBV maps were compared between gadoteridol and various doses of ferumoxytol using an automated method. To subjectively assess the quality of the CBV maps, two blinded readers also assessed visual conspicuity of the putamen. STATISTICAL TESTS: Linear mixed effect model was used for statistical comparison. RESULTS: Compared to gadoteridol, 1 mg/kg ferumoxytol showed no difference in CNR (P = 0.6505), peak ΔR2*, and rCBV in the putamen (P = 0.2669, 0.0871) or in the thalamus (P = 0.517, 0.9787); 2 mg/kg ferumoxytol increased peak ΔR2* as well as the CNR (P < 0.0001), but also mildly increased rCBV in putamen and globus pallidus (P = 0.0005, 0.0012). Signal intensities during first pass remained highly above the noise level, with overlapping of 95% confidence intervals with noise only in 3 out of 162 tested regions. Compared to gadoteridol, the visual image quality showed mild improvement with 1 mg/kg (P = 0.02) and marked improvement with 2 mg/kg ferumoxytol (P < 0.0001). DATA CONCLUSION: 1 mg/kg ferumoxytol provides similar imaging results to standard gadoteridol for DSC-MRI, and 2 mg/kg has a benefit of increased CNR, but may also result in mildly increased rCBV values. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2018;48:441-448.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。