Impact of detecting potentially serious incidental findings during multi-modal imaging

多模态成像过程中发现潜在严重意外发现的影响

阅读:1

Abstract

Background: There are limited data on the impact of feedback of incidental findings (IFs) from research imaging.  We evaluated the impact of UK Biobank's protocol for handling potentially serious IFs in a multi-modal imaging study of 100,000 participants (radiographer 'flagging' with radiologist confirmation of potentially serious IFs) compared with systematic radiologist review of all images. Methods: Brain, cardiac and body magnetic resonance, and dual-energy x-ray absorptiometry scans from the first 1000 imaged UK Biobank participants were independently assessed for potentially serious IFs using both protocols. We surveyed participants with potentially serious IFs and their GPs up to six months after imaging to determine subsequent clinical assessments, final diagnoses, emotional, financial and work or activity impacts. Results: Compared to systematic radiologist review, radiographer flagging resulted in substantially fewer participants with potentially serious IFs (179/1000 [17.9%] versus 18/1000 [1.8%]) and a higher proportion with serious final diagnoses (21/179 [11.7%] versus 5/18 [27.8%]). Radiographer flagging missed 16/21 serious final diagnoses (i.e., false negatives), while systematic radiologist review generated large numbers of non-serious final diagnoses (158/179) (i.e., false positives). Almost all (90%) participants had further clinical assessment (including invasive procedures in similar numbers with serious and non-serious final diagnoses [11 and 12 respectively]), with additional impact on emotional wellbeing (16.9%), finances (8.9%), and work or activities (5.6%). Conclusions: Compared with systematic radiologist review, radiographer flagging missed some serious diagnoses, but avoided adverse impacts for many participants with non-serious diagnoses. While systematic radiologist review may benefit some participants, UK Biobank's responsibility to avoid both unnecessary harm to larger numbers of participants and burdening of publicly-funded health services suggests that radiographer flagging is a justifiable approach in the UK Biobank imaging study. The potential scale of non-serious final diagnoses raises questions relating to handling IFs in other settings, such as commercial and public health screening.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。