Breast Cancer Risk and Mammographic Density Assessed with Semiautomated and Fully Automated Methods and BI-RADS

采用半自动和全自动方法以及BI-RADS评估乳腺癌风险和乳腺X线摄影密度。

阅读:1

Abstract

Purpose To compare three metrics of breast density on full-field digital mammographic (FFDM) images as predictors of future breast cancer risk. Materials and Methods This institutional review board-approved study included 125 women with invasive breast cancer and 274 age- and race-matched control subjects who underwent screening FFDM during 2004-2013 and provided informed consent. The percentage of density and dense area were assessed semiautomatically with software (Cumulus 4.0; University of Toronto, Toronto, Canada), and volumetric percentage of density and dense volume were assessed automatically with software (Volpara; Volpara Solutions, Wellington, New Zealand). Clinical Breast Imaging Reporting and Data System (BI-RADS) classifications of breast density were extracted from mammography reports. Odds ratios and 95% confidence intervals (CIs) were estimated by using conditional logistic regression stratified according to age and race and adjusted for body mass index, parity, and menopausal status, and the area under the receiver operating characteristic curve (AUC) was computed. Results The adjusted odds ratios and 95% CIs for each standard deviation increment of the percentage of density, dense area, volumetric percentage of density, and dense volume were 1.61 (95% CI: 1.19, 2.19), 1.49 (95% CI: 1.15, 1.92), 1.54 (95% CI: 1.12, 2.10), and 1.41 (95% CI: 1.11, 1.80), respectively. Odds ratios for women with extremely dense breasts compared with those with scattered areas of fibroglandular density were 2.06 (95% CI: 0.85, 4.97) and 2.05 (95% CI: 0.90, 4.64) for BI-RADS and Volpara density classifications, respectively. Clinical BI-RADS was more accurate (AUC, 0.68; 95% CI: 0.63, 0.74) than Volpara (AUC, 0.64; 95% CI: 0.58, 0.70) and continuous measures of percentage of density (AUC, 0.66; 95% CI: 0.60, 0.72), dense area (AUC, 0.66; 95% CI: 0.60, 0.72), volumetric percentage of density (AUC, 0.64; 95% CI: 0.58, 0.70), and density volume (AUC, 0.65; 95% CI: 0.59, 0.71), although the AUC differences were not statistically significant. Conclusion Mammographic density on FFDM images was positively associated with breast cancer risk by using the computer assisted methods and BI-RADS. BI-RADS classification was as accurate as computer-assisted methods for discrimination of patients from control subjects. (©) RSNA, 2016.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。