Simultaneous Measurement of Temperature and Refractive Index Using Michelson Interferometer Based on Waist-Enlarged Fiber Bitaper

利用腰扩光纤光栅迈克尔逊干涉仪同时测量温度和折射率

阅读:10
作者:Na Zhao, Zelin Wang, Zhongkai Zhang, Qijing Lin, Kun Yao, Liangquan Zhu, Bian Tian, Libo Zhao, Ping Yang, Zhuangde Jiang

Abstract

An all-fiber temperature and refractive dual-parameter-sensing Michelson interferometer is designed based on the waist-enlarged bitaper. At 5 mm from the fiber end, the waist-enlarged bitaper is manually spliced and the probe is formed. Since the input light encounters the waist-enlarged bitaper, it will excite high-order modes to transmit in the fiber cladding, and there will be an optical path difference between the basic mode and the higher-order mode. The light transmitted in the core and cladding is reflected upon encountering the fiber end face and the interference occurs due to the optical path difference between basic mode and higher-order mode. Changes in temperature and refractive index at the fiber probe can be detected by monitoring the interference fringes. The refractive response sensitivity is -191.06 dBm/RIU from 1.351 RIU to 1.4027 RIU, and the temperature response sensitivity is 0.12 nm/°C from 11 °C to 98 °C. Through the sensitivity matrix equation, the superimposed refractive index and temperature signals can be effectively demodulated. The sensor has the advantages of multi-parameter measurement, compact structure, low cost, easy fabrication and high reliability.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。