Examining pupil characteristics and relative afferent pupil defect prevalence in Syrian patients

检查叙利亚患者的瞳孔特征和传入性瞳孔障碍的相对患病率

阅读:1

Abstract

PURPOSE: This study aims to explore pupil characteristics in a cohort of Syrian patients across different age groups and under varying luminance conditions, both pre- and post-pupil dilation. Additionally, the research seeks to ascertain the prevalence of the relative afferent pupillary defect (RAPD) within this patient population and to compare multiple test results to the established gold standard for diagnosing RAPD. MATERIALS AND METHODS: This is a cross-sectional study encompassing 178 patients who sought medical attention at the Al-Mowasat University Hospital clinics in Damascus, Syria, from March 1, 2020 to June 1, 2021. The research process involved a comprehensive review of the patients' complaints and medical records, coupled with measurements of pupil diameters and amplitudes under conditions of low and high luminance using the automatic pupil measurement program of the Sirius topography device. The study investigated the incidence of anisocoria, abnormal pupil size, and RAPD. Special cases were deliberated, and data were meticulously collected, organized, and analyzed using a direct statistical approach. RESULTS: Anisocoria exceeding 2 mm or abnormal pupil size was identified in 11 (6.18%) of the patients included in this study. The average pupil diameter at low luminance pre-dilation was measured at 3.59 ± 1.36 mm, while at high luminance, it was 1.93 ± 0.80 mm. Females exhibited a higher average pupil diameter compared to males (P < 0.001). A significant decreasing trend in pupil diameter with age was observed across three age groups (P < 0.001). A very strong positive correlation was discovered between constriction amplitude and pupil diameter, both pre- and post-dilation. Moreover, the dilation amplitude was observed to increase with age alongside a decrease in pupil diameter. The incidence of RAPD based on clinical examination was determined to be 7.9%, serving as the gold standard for comparison. The pupillometer test displayed accuracy with a matching rate of 98.2% compared to the gold standard. Among RAPD patients, older individuals with larger pupil diameters predominated in the sample. CONCLUSIONS: Highlighting the size and reactivity of pupils is crucial, especially in the elderly population, as these characteristics can serve as key indicators of underlying pathologies. The objective assessment and regular monitoring of these parameters are essential for the early detection and management of potential conditions. Notably, the pupillometer demonstrates superior accuracy in detecting RAPD compared to swinging high-luminance tests both before and after dilation. This underscores the importance of incorporating advanced technology for precise and reliable evaluation of pupillary responses, particularly in clinical settings where accurate diagnostic information is critical for optimal patient care.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。