Validation of Oura ring energy expenditure and steps in laboratory and free-living

在实验室和自由生活中验证 Oura 环的能量消耗和步骤

阅读:1

Abstract

BACKGROUND: Commercial activity trackers are increasingly used in research and compared with research-based accelerometers are often less intrusive, cheaper, with improved storage and battery capacity, although typically less validated. The present study aimed to determine the validity of Oura Ring step-count and energy expenditure (EE) in both laboratory and free-living. METHODS: Oura Ring EE was compared against indirect calorimetry in the laboratory, followed by a 14-day free-living study with 32 participants wearing an Oura Ring and reference monitors (three accelerometers positioned at hip, thigh, and wrist, and pedometer) to evaluate Oura EE variables and step count. RESULTS: Strong correlations were shown for Oura versus indirect calorimetry in the laboratory (r = 0.93), and versus reference monitors for all variables in free-living (r ≥ 0.76). Significant (p < 0.05) mean differences for Oura versus reference methods were found for laboratory measured sitting (- 0.12 ± 0.28 MET), standing (- 0.27 ± 0.33 MET), fast walk (- 0.82 ± 1.92 MET) and very fast run (- 3.49 ± 3.94 MET), and for free-living step-count (2124 ± 4256 steps) and EE variables (MET: - 0.34-0.26; TEE: 362-494 kcal; AEE: - 487-259 kcal). In the laboratory, Oura tended to underestimate EE with increasing discrepancy as intensity increased. The combined activities and slow running in the laboratory, and all MET placements, TEE hip and wrist, and step count in free-living had acceptable measurement errors (< 10% MAPE), whereas the remaining free-living variables showed close to (≤13.2%) acceptable limits. CONCLUSION: This is the first study investigating the validity of Oura Ring EE against gold standard methods. Oura successfully identified major changes between activities and/or intensities but was less responsive to detailed deviations within activities. In free-living, Oura step-count and EE variables tightly correlated with reference monitors, though with systemic over- or underestimations indicating somewhat low intra-individual validity of the ring versus the reference monitors. However, the correlations between the devices were high, suggesting that the Oura can detect differences at group-level for active and total energy expenditure, as well as step count.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。