Optimal specimen collection and transport methods for the detection of avian influenza virus and Newcastle disease virus

检测禽流感病毒和新城疫病毒的最佳标本采集和运输方法

阅读:1

Abstract

BACKGROUND: Active and passive surveillance for avian influenza virus (AIV) and Newcastle disease virus (NDV) is widespread in commercial poultry worldwide, therefore optimization of sample collection and transport would be valuable to achieve the best sensitivity and specificity possible, and to develop the most accurate and efficient testing programs. A H7N2 low pathogenicity (LP) AIV strain was selected and used as an indicator virus because it is present in lower concentrations in swabbings and thus requires greater sensitivity for detection compared to highly pathogenic (HP) AIV. For similar reasons a mesogenic strain of NDV was selected. Using oro-pharyngeal and cloacal swabs collected from chickens experimentally exposed to the viruses we evaluated the effects of numerous aspects of sample collection and transport: 1) swab construction material (flocked nylon, non-flocked Dacron, or urethane foam), 2) transport media (brain heart infusion broth [BHI] or phosphate buffered saline [PBS]), 3) media volume (2 ml or 3.5 ml), 4) transporting the swab wet in the vial or removing the swab prior to transport, or transporting the swab dry with no media, and 5) single swabs versus pooling 5 or 11 swabs per vial. RESULTS: Using real-time RT-PCR (rRT-PCR), virus isolation (VI) and commercial antigen detection immunoassays for AIV we observed statistically significant differences and consistent trends with some elements of sample collection and transport; media, dry transport and swab construction. Conversely, the number of swabs pooled (1, 5 or 11) and whether the swab was removed prior to transport did not impact virus detection. Similarly, with NDV detection by both VI and rRT-PCR was not affected by the numbers of swabs collected in a single vial (1, 5 or 11). CONCLUSIONS: We observed that flocked and foam swabs were superior to non-flocked swabs, BHI media was better than PBS, and transporting swabs wet was better for virus recovery and detection than transporting them dry. There was no observable difference in detection whether the swab was removed prior to transport or left in the vial. Also, with both AIV and NDV, there was no observed difference in virus detection between pools of 1, 5 or 11 swabs.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。