Two-body wear of occlusal splint materials from subtractive computer-aided manufacturing and three-dimensional printing

计算机辅助减材制造和三维打印咬合夹板材料的双体磨损

阅读:8
作者:Felix Schmeiser, Uwe Baumert, Bogna Stawarczyk

Conclusions

3DP substrates showed no differences in two-body wear compared to CAM ones but are more likely to show a fracture. None of the tested materials caused an abrasion on human teeth structure. Clinical relevance: While therapies with occlusal splint materials are rising, 3DP offers a promising alternative to CAM in terms of production accuracy and therapeutic success at reduced costs.

Material and methods

Forty-eight substrates (n = 12/material) in the design of a mandibular first molar were fabricated using CAM (CAM-TD, Thermeo, pro3dure medical GmbH, Iserlohn, Germany; CAM-CL, CLEARsplint, Astron Dental Corporation, Lake Zurich, USA) and 3DP (3DP-GI, GR22 flex, pro3dure medical GmbH; 3DP-KY, KeySplint soft, Keystone Industries, Gibbstown, USA). The substrates were subjected to mastication simulation (120,000 cycles, 37 °C, 50 N, 1.3 Hz) opposed to enamel antagonists. The two-body wear was measured through matching of the scanned substrates before and after aging using Gaussian best-fit method. The damage patterns were categorized and evaluated based on microscopic examinations. Data was analyzed using Kolmogorov-Smirnov test followed by 1-way analysis of variance (ANOVA). Pearson correlation was calculated between vertical and volumetric material loss. The failure types were analyzed with Chi2-test and Ciba Geigy table.

Methods

Forty-eight substrates (n = 12/material) in the design of a mandibular first molar were fabricated using CAM (CAM-TD, Thermeo, pro3dure medical GmbH, Iserlohn, Germany; CAM-CL, CLEARsplint, Astron Dental Corporation, Lake Zurich, USA) and 3DP (3DP-GI, GR22 flex, pro3dure medical GmbH; 3DP-KY, KeySplint soft, Keystone Industries, Gibbstown, USA). The substrates were subjected to mastication simulation (120,000 cycles, 37 °C, 50 N, 1.3 Hz) opposed to enamel antagonists. The two-body wear was measured through matching of the scanned substrates before and after aging using Gaussian best-fit method. The damage patterns were categorized and evaluated based on microscopic examinations. Data was analyzed using Kolmogorov-Smirnov test followed by 1-way analysis of variance (ANOVA). Pearson correlation was calculated between vertical and volumetric material loss. The failure types were analyzed with Chi2-test and Ciba Geigy table.

Results

No difference in two-body wear results between all materials was found (p = 0.102). Fatigue substrates showed a perforation for CAM and a fracture for 3DP. No abrasion losses on the antagonists were detected. Conclusions: 3DP substrates showed no differences in two-body wear compared to CAM ones but are more likely to show a fracture. None of the tested materials caused an abrasion on human teeth structure. Clinical relevance: While therapies with occlusal splint materials are rising, 3DP offers a promising alternative to CAM in terms of production accuracy and therapeutic success at reduced costs.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。