Clinical Performance of a Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Method for Detection of Certain blaKPC-Containing Plasmids

基质辅助激光解吸电离飞行时间质谱法检测某些含blaKPC质粒的临床性能

阅读:1

Abstract

Rapid detection of blaKPC-containing organisms can significantly impact infection control and clinical practices, as well as therapeutic choices. Current molecular and phenotypic methods to detect these organisms, however, require additional testing beyond routine organism identification. In this study, we evaluated the clinical performance of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) to detect pKpQIL_p019 (p019)-an ∼11,109-Da protein associated with certain blaKPC-containing plasmids that was previously shown to successfully track a clonal outbreak of blaKPC-pKpQIL-Klebsiella pneumoniae in a proof-of-principle study (A. F. Lau, H. Wang, R. A. Weingarten, S. K. Drake, A. F. Suffredini, M. K. Garfield, Y. Chen, M. Gucek, J. H. Youn, F. Stock, H. Tso, J. DeLeo, J. J. Cimino, K. M. Frank, and J. P. Dekker, J Clin Microbiol 52:2804-2812, 2014, http://dx.doi.org/10.1128/JCM.00694-14). PCR for the p019 gene was used as the reference method. Here, blind analysis of 140 characterized Enterobacteriaceae isolates using two protein extraction methods (plate extraction and tube extraction) and two peak detection methods (manual and automated) showed sensitivities and specificities ranging from 96% to 100% and from 95% to 100%, respectively (2,520 spectra analyzed). Feasible laboratory implementation methods (plate extraction and automated analysis) demonstrated 96% sensitivity and 99% specificity. All p019-positive isolates (n = 26) contained blaKPC and were carbapenem resistant. Retrospective analysis of an additional 720 clinical Enterobacteriaceae spectra found an ∼11,109-Da signal in nine spectra (1.3%), including seven from p019-containing, carbapenem-resistant isolates (positive predictive value [PPV], 78%). Instrument tuning had a significant effect on assay sensitivity, highlighting important factors that must be considered as MALDI-TOF MS moves into applications beyond microbial identification. Using a large blind clinical data set, we have shown that spectra acquired for routine organism identification can also be analyzed automatically in real time at high throughput, at no additional expense to the laboratory, to enable rapid detection of potentially blaKPC-containing carbapenem-resistant isolates, providing early and clinically actionable results.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。