Precision of vancomycin and daptomycin MICs for methicillin-resistant Staphylococcus aureus and effect of subculture and storage

万古霉素和达托霉素对耐甲氧西林金黄色葡萄球菌的最低抑菌浓度(MIC)的精确性及其对传代培养和储存的影响

阅读:1

Abstract

The reproducibility of vancomycin and daptomycin MICs, measured by broth microdilution (BMD) and Etest, was prospectively assessed for 10 methicillin-resistant Staphylococcus aureus (MRSA) isolates from the blood samples from patients on vancomycin therapy. The isolates were tested at the time of isolation from blood and following 5, 10, and 20 subcultures and at 1, 3, 6, and 12 months of storage at -70 °C. The MICs were determined by Etest and BMD using two different manufacturers (BBL and Difco) of cation-adjusted Mueller-Hinton broth (CA-MHB), and using three different drug powders: vancomycin from Sigma, vancomycin from Novation, and daptomycin from Cubist. The antimicrobial concentrations tested were 0.25, 0.5, 0.75, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, and 4.0 μg/ml. Two isolates were vancomycin intermediate and daptomycin nonsusceptible, and two isolates had reduced susceptibility to vancomycin (BMD MIC, 1.5 or 2.0 μg/ml). The vancomycin MICs were significantly higher in the BBL CA-MHB than those in the Difco CA-MHB, and with Sigma versus Novation vancomycin powder. The daptomycin MICs were also significantly higher in the BBL CA-MHB. The Etest MICs were significantly higher than those obtained by BMD for vancomycin but not for daptomycin. The average precision of the vancomycin BMD MICs when analyzing 20 results was ± 1.10-fold log2 dilutions, and it was ± 1.67-fold for daptomycin (10 results). The average precision for Etest was ± 1.11-fold for vancomycin and ± 1.16-fold for daptomycin. No significant change in MICs was noted following 5, 10, or 20 subcultures or at up to 6 months of frozen storage. However, the vancomycin MICs alone were significantly lower (0.74-fold) following 12 months of frozen storage. From these data, despite variations in CA-MHB and antimicrobial powder, the MIC result precision was <0.5 log2 dilutions in a single laboratory, suggesting that testing interdilution MICs (e.g., MICs between serial 2-fold dilutions) is a possibility. A more accurate method for measuring vancomycin MIC results is thus possible, but further standardization of BMD testing would be required to achieve this goal.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。