Sensitivity of the ISO 6579:2002/Amd 1:2007 standard method for detection of Salmonella spp. on mesenteric lymph nodes from slaughter pigs

ISO 6579:2002/Amd 1:2007标准方法检测屠宰猪肠系膜淋巴结中沙门氏菌属的灵敏度

阅读:1

Abstract

The ISO 6579:2002/Amd 1:2007 (ISO) standard has been the bacteriological standard method used in the European Union for the detection of Salmonella spp. in pig mesenteric lymph nodes (MLN), but there are no published estimates of the diagnostic sensitivity (Se) of the method in this matrix. Here, the Se of the ISO (Se(ISO)) was estimated on 675 samples selected from two populations with different Salmonella prevalences (14 farms with a ≥ 20% prevalence and 13 farms with a <20% prevalence) and through the use of latent-class models in concert with Bayesian inference, assuming 100% ISO specificity, and an invA-based PCR as the second diagnostic method. The Se(ISO) was estimated to be close to 87%, while the sensitivity of the PCR reached up to 83.6% and its specificity was 97.4%. Interestingly, the bacteriological reanalysis of 33 potential false-negative (PCR-positive) samples allowed isolation of 19 (57.5%) new Salmonella strains, improving the overall diagnostic accuracy of the bacteriology. Considering the usual limitations of bacteriology regarding Se, these results support the adequacy of the ISO for the detection of Salmonella spp. from MLN and also that of the PCR-based method as an alternative or complementary (screening) test for the diagnosis of pig salmonellosis, particularly considering the cost and time benefits of the molecular procedure.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。