Simultaneous quantification of 20 synthetic cannabinoids and 21 metabolites, and semi-quantification of 12 alkyl hydroxy metabolites in human urine by liquid chromatography-tandem mass spectrometry

液相色谱-串联质谱法同时定量分析人尿中 20 种合成大麻素和 21 种代谢物以及半定量分析 12 种烷基羟基代谢物

阅读:5
作者:Karl B Scheidweiler, Marilyn A Huestis

Abstract

Clandestine laboratories constantly produce new synthetic cannabinoids to circumvent legislative efforts, complicating toxicological analysis. No extensive synthetic cannabinoid quantitative urinary methods are reported in the literature. We developed and validated a liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for simultaneously quantifying JWH-018, JWH-019, JWH-073, JWH-081, JWH-122, JWH-200, JWH-210, JWH-250, JWH-398, RCS-4, AM-2201, MAM-2201, UR-144, CP 47,497-C7, CP 47,497-C8 and their metabolites, and JWH-203, AM-694, RCS-8, XLR-11 and HU-210 parent compounds in urine. Non-chromatographically resolved alkyl hydroxy metabolite isomers were considered semi-quantitative. β-Glucuronidase hydrolyzed urine was extracted with 1ml Biotage SLE+ columns. Specimens were reconstituted in 150μL mobile phase consisting of 50% A (0.01% formic acid in water) and 50% B (0.01% formic acid in 50:50 methanol:acetonitrile). 4 and 25μL injections were performed to acquire data in positive and negative ionization modes, respectively. The LC-MS/MS instrument consisted of a Shimadzu UFLCxr system and an ABSciex 5500 Qtrap mass spectrometer with an electrospray source. Gradient chromatographic separation was achieved utilizing a Restek Ultra Biphenyl column with a 0.5ml/min flow rate and an overall run time of 19.5 and 11.4min for positive and negative mode methods, respectively. Quantification was by multiple reaction monitoring with CP 47,497 compounds and HU-210 ionized via negative polarity; all other analytes were acquired in positive mode. Lower and upper limits of linearity were 0.1-1.0 and 50-100μg/l (r(2)>0.994). Validation parameters were evaluated at three concentrations spanning linear dynamic ranges. Inter-day analytical recovery (bias) and imprecision (N=20) were 88.3-112.2% and 4.3-13.5% coefficient of variation, respectively. Extraction efficiencies and matrix effect (N=10) were 44-110 and -73 to 52%, respectively. We present a novel LC-MS/MS method for simultaneously quantifying 20 synthetic cannabinoids and 21 metabolites, and semi-quantifying 12 alkyl hydroxy metabolites in urine.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。