Conclusion
Higher GV is associated with increased thrombotic biomarkers in type 1 diabetes but only in those with concomitant insulin resistance.
Methods
We conducted secondary analyses on continuous glucose monitoring (CGM) using baseline observational data from three randomised controlled trials and assessed the relationship with established vascular markers. We used standard CGM summary statistics and principal component analysis to generate individual glucose variability signatures for each participant. Cluster analysis was then employed to establish three GV clusters (low, intermediate, or high GV, respectively). The relationship with thrombotic biomarkers was then investigated according to insulin resistance, assessed as estimated glucose disposal rate (eGDR).
Results
Of 107 patients, 45%, 37%, and 18% of patients were assigned into low, intermediate, and high GV clusters, respectively. Thrombosis biomarkers (including fibrinogen, plasminogen activator inhibitor-1, tissue factor activity, and tumour necrosis factor-alpha) increased in a stepwise fashion across all three GV clusters; this increase in thrombosis markers was evident in the presence of low but not high eGDR and at a threshold of eGDR <5.1 mg/kg/min.