Inhibition of interleukin-5 induced false positive anti-drug antibody responses against mepolizumab through the use of a competitive blocking antibody

通过使用竞争性阻断抗体抑制白细胞介素 5 引起的针对美泊利单抗的假阳性抗药抗体反应

阅读:15
作者:Karen Liao, Erik Meyer, Thomas N Lee, Amy Loercher, Daniel Sikkema

Abstract

Mepolizumab, a humanized IgG1 monoclonal antibody that blocks native homodimeric interleukin-5 (IL-5) from binding to the IL-5 receptor, has recently been approved for treatment of severe eosinophilic asthma. Our initial immunogenicity assay method for phase I and II studies utilized a bridging electrochemiluminescence format with biotin and ruthenium-labelled mepolizumab linked by anti-drug antibodies (ADA). We discovered that IL-5 significantly increased in dosed subjects from a phase II study and that the increased IL-5 was in the form of a drug-bound complex. We demonstrated that the elevated drug-bound IL-5 produced false-positive response in the in vitro ADA assay, in which drug-bound IL-5 dissociated and then bridged mepolizumab conjugates to yield positive signal. To eliminate the IL-5 interference, we compared two strategies: a solid-phase immunodepletion of IL-5 and an in-solution IL-5 immunocompetition. We identified the best competitive antibody for each purpose. We found both methods demonstrated similar effectiveness in reducing the false positive signal in IL-5 spiked samples; however, the in-solution immunocompetition for IL-5 had fewer false positives in study samples. Additionally, the in-solution immunocompetition method was experimentally simpler to execute. We modified the ADA assay by adding a pre-treatment step with a mepolizumab competitive anti- IL-5 antibody. Using this new method, we retested clinical samples from two phase II studies (MEA112997 and MEA114092). The confirmed ADA positive incidence was reduced from 29% and 61% to 1% and 8% with the modified in-solution immune inhibition method. Target interference is a fairly common problem facing immunogenicity testing, and target-induced false positive cannot be distinguished from true ADA response by the commonly used drug competitive confirmation assay. The approach and method used here for resolving target interference in ADA detection will be useful for differentiating between a true ADA response and target induced false positive as well as similar challenges in other programs.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。