Serum Thyroglobulin Measurement Following Surgery Without Radioactive Iodine for Differentiated Thyroid Cancer: A Systematic Review

分化型甲状腺癌手术后未接受放射性碘治疗时血清甲状腺球蛋白测定:系统评价

阅读:2

Abstract

Background: The utility of serum thyroglobulin (Tg) measurement following partial thyroidectomy or total/near-total thyroidectomy without radioactive iodine (RAI) for differentiated thyroid cancer is unclear. This systematic review examines the diagnostic accuracy of serum Tg measurement for persistent, recurrent, and/or metastatic cancer in these situations. Methods: Ovid MEDLINE, Embase, and Cochrane Central were searched in October 2021 for studies on Tg measurement following partial thyroidectomy or total/near-total thyroidectomy without or before RAI. Quality assessment was performed, and evidence was synthesized qualitatively. Results: Thirty-seven studies met inclusion criteria. Four studies (N = 561) evaluated serum Tg measurement following partial thyroidectomy, five studies (N = 751) evaluated Tg measurement following total/near-total thyroidectomy without RAI, and 28 studies (N = 7618) evaluated Tg measurement following total or near-total thyroidectomy before RAI administration. Following partial thyroidectomy, Tg measurement was not accurate for diagnosing recurrence or metastasis, or estimates were imprecise. Following total/near-total thyroidectomy without RAI, evidence was limited due to few studies with very low rates of recurrence or metastasis, but indicated that Tg levels were usually stable and low. For Tg measurements before RAI administration, diagnostic accuracy for metastatic disease or persistence varied, although sensitivity appeared high (but specificity low) at a cutoff of >1 to 2.5 ng/mL. However, applicability to patients who do not undergo RAI is uncertain because patients selected for RAI are likely to represent a higher risk group. The evidence was very low quality for all scenarios. All studies had methodological limitations, and there was variability in the Tg thresholds evaluated, patient populations, outcomes assessed, and other factors. Conclusions: Very limited evidence suggests low utility of Tg measurement for identifying recurrent or metastatic disease following partial thyroidectomy. Following total/near-total thyroidectomy, Tg levels using a cutoff of 1-2.5 ng/mL might identify patients at low risk for persistent or metastatic disease. Additional research is needed to clarify the role of Tg measurement in these settings, determine optimal Tg thresholds, and determine appropriate measurement intervals.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。