Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity

比较不同强度自行车运动中肌肉氧饱和度与常见运动表现和生理指标的可靠性

阅读:1

Abstract

INTRODUCTION: Wearable near-infrared spectroscopy (NIRS) measurements of muscle oxygen saturation (SmO(2)) demonstrated good test-retest reliability at rest. We hypothesized SmO(2) measured with the Moxy monitor at the vastus lateralis (VL) would demonstrate good reliability across intensities. For relative reliability, SmO(2) will be lower than volume of oxygen consumption (V̇O(2)) and heart rate (HR), higher than concentration of blood lactate accumulation ([BLa]) and rating of perceived exertion (RPE). We aimed to estimate the reliability of SmO(2) and common physiological measures across exercise intensities, as well as to quantify within-participant agreement between sessions. METHODS: Twenty-one trained cyclists completed two trials of an incremental multi-stage cycling test with 5 min constant workload steps starting at 1.0 watt per kg bodyweight (W·kg(-1)) and increasing by 0.5 W kg(-1) per step, separated by 1 min passive recovery intervals until maximal task tolerance. SmO(2), HR, V̇O(2), [BLa], and RPE were recorded for each stage. Continuous measures were averaged over the final 60 s of each stage. Relative reliability at the lowest, median, and highest work stages was quantified as intraclass correlation coefficient (ICC). Absolute reliability and within-subject agreement were quantified as standard error of the measurement (SEM) and minimum detectable change (MDC). RESULTS: Comparisons between trials showed no significant differences within each exercise intensity for all outcome variables. ICC for SmO(2) was 0.81-0.90 across exercise intensity. ICC for HR, V̇O(2), [BLa], and RPE were 0.87-0.92, 0.73-0.97, 0.44-0.74, 0.29-0.70, respectively. SEM (95% CI) for SmO(2) was 5 (3-7), 6 (4-9), and 7 (5-10)%, and MDC was 12%, 16%, and 18%. DISCUSSION: Our results demonstrate good-to-excellent test-retest reliability for SmO(2) across intensity during an incremental multi-stage cycling test. V̇O(2) and HR had excellent reliability, higher than SmO(2). [BLa] and RPE had lower reliability than SmO(2). Muscle oxygen saturation measured by wearable NIRS was found to have similar reliability to V̇O(2) and HR, and higher than [BLa] and RPE across exercise intensity, suggesting that it is appropriate for everyday use as a non-invasive method of monitoring internal load alongside other metrics.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。