Assessing the accuracy of the recording and reporting of malaria rapid diagnostic test results in four African countries: methods and key results

评估非洲四个国家疟疾快速诊断检测结果记录和报告的准确性:方法和主要结果

阅读:1

Abstract

BACKGROUND: Rapid diagnostic test (RDT) results are the foundation of both case management and malaria surveillance across sub-Saharan Africa. However, RDT results may be misrecorded in health facility registers by healthcare workers (HCWs), either unintentionally or deliberately, for example, to justify treatment based on clinical judgment. A multi-country evaluation was conducted to quantify the extent of RDT misrecording and identify factors associated with recording and reporting accuracy. This report summarizes the study's methods, key findings, and implications for improving malaria RDT data quality. METHODS: A mixed-methods observational study was implemented in Benin, Côte d'Ivoire, Nigeria, and Uganda in 2023. At participating health facilities, images of RDTs were captured at the point of care and later reviewed by a trained, external panel. Agreement between the panel's interpretation and the result recorded in the register was assessed using weighted mean Cohen's kappa (κ). Secondary objectives included identifying factors associated with inaccurate recording, assessing the durability of RDT results after 1 month of storage, evaluating accuracy of data obtained from the District Health Information System 2 (DHIS2), and measuring the observer effect of the start of the study on test positivity rates (TPR) reported to DHIS2. RESULTS: A total of 102,337 RDT results was observed. Agreement between register-recorded results and the external panel was high, ranging from κ = 0.80 (95% confidence interval [CI] 0.75, 0.85) in Nigeria to κ = 0.88 (95% CI 0.84, 0.92) in Benin. HCWs were more likely to misrecord results as positive (range: 5.1-7.3%) than negative (range: 0.7-3.7%), and patient age was associated with misrecording results in all countries except Nigeria. After the study began in Côte d'Ivoire, TPRs reported from the DHIS2 declined significantly more in study than control facilities (rate ratio: 0.80, 95% CI 0.76, 0.84). CONCLUSIONS: Although HCWs generally recorded RDT results accurately, the disproportionately higher proportion of results misrecorded as positive raises concern about possible intentional misreporting. The observed TPR decrease after study onset in Côte d'Ivoire suggests some HCWs can be motivated to reduce misrecording and improve the quality of malaria case management and surveillance data.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。