Internal Temperature Measurement of Optically Levitated Particles in Vacuum by Raman Thermometry

利用拉曼测温法测量真空中光悬浮粒子的内部温度

阅读:5

Abstract

An optical levitation system in a vacuum is an efficient system to investigate the dynamics of isolated micro- and nanoparticles. However, the motion and stability of the trapped particles in this system can be affected by the internal temperature, which remains a challenge to measure. Conventional methods are constrained by material specificity or lack the capability for direct temperature measurement. Here, we demonstrate the application of Raman thermometry for non-contact temperature detection of an optically levitated fused silica sphere in vacuum. In addition, the experimental results reveal a linear increase in particle temperature with laser power, consistent with photothermal theory. The integration of Raman thermometry with the optical levitation system enables high-precision thermal sensing at the microscale, offering significant potential for applications in precision metrology and fundamental physics.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。