Three-Dimensional Amide Proton Transfer-Weighted Imaging for Differentiating between Glioblastoma, IDH-Wildtype and Primary Central Nervous System Lymphoma

三维酰胺质子转移加权成像用于鉴别胶质母细胞瘤、IDH野生型和原发性中枢神经系统淋巴瘤

阅读:2

Abstract

Distinguishing primary central nervous system lymphoma (PCNSL) from glioblastoma, isocitrate dehydrogenase (IDH)-wildtype is sometimes hard. Because the role of operation on them varies, accurate preoperative diagnosis is crucial. In this study, we evaluated whether a specific kind of chemical exchange saturation transfer imaging, i.e., amide proton transfer-weighted (APTw) imaging, was useful to distinguish PCNSL from glioblastoma, IDH-wildtype. A total of 14 PCNSL and 27 glioblastoma, IDH-wildtype cases were evaluated. There was no significant difference in the mean APTw signal values between the two groups. However, the percentile values from the 1st percentile to the 20th percentile APTw signals and the width(1-100) APTw signals significantly differed. The highest area under the curve was 0.796, which was obtained from the width(1-100) APTw signal values. The sensitivity and specificity values were 64.3% and 88.9%, respectively. APTw imaging was useful to distinguish PCNSL from glioblastoma, IDH-wildtype. To avoid unnecessary aggressive surgical resection, APTw imaging is recommended for cases in which PCNSL is one of the differential diagnoses.