Prone whole-breast irradiation using three-dimensional conformal radiotherapy in women undergoing breast conservation for early disease yields high rates of excellent to good cosmetic outcomes in patients with large and/or pendulous breasts

对于早期乳腺癌患者,采用三维适形放射治疗进行保乳手术,可使乳房较大和/或下垂的患者获得较高的美容效果,且疗效优良率很高。

阅读:1

Abstract

PURPOSE: To report our institution's experience using prone positioning for three-dimensional conformal radiotherapy (3D-CRT) to deliver post-lumpectomy whole breast irradiation (WBI) in a cohort of women with large and/or pendulous breasts, to determine the rate of acute and late toxicities and, more specifically, cosmetic outcomes. We hypothesized that using 3D-CRT for WBI in the prone position would reduce or eliminate patient and breast size as negative prognostic indicators for toxicities associated with WBI. METHODS AND MATERIALS: From 1998 to 2006, 110 cases were treated with prone WBI using 3D-CRT. The lumpectomy, breast target volumes, heart, and lung were contoured on all computed tomography scans. A dose of 45-50 Gy was prescribed to the breast volume using standard fractionation schemes. The planning goals were ≥95% of prescription to 95% of the breast volume, and 100% of boost dose to 95% of lumpectomy planning target volume. Toxicities and cosmesis were prospectively scored using the Common Terminology Criteria for Adverse Effects Version 3.0 and the Harvard Scale. The median follow-up was 40 months. RESULTS: The median body mass index (BMI) was 33.6 kg/m(2), and median breast volume was 1396 cm(3). The worst toxicity encountered during radiation was Grade 3 dermatitis in 5% of our patient population. Moist desquamation occurred in 16% of patients, with only 2% of patients with moist desquamation outside the inframammary/axillary folds. Eleven percent of patients had Grade ≥2 late toxicities, including Grade 3 induration/fibrosis in 2%. Excellent to good cosmesis was achieved in 89%. Higher BMI was associated with moist desquamation and breast pain, but BMI and breast volume did not impact fibrosis or excellent to good cosmesis. CONCLUSION: In patients with higher BMI and/or large-pendulous breasts, delivering prone WBI using 3D-CRT results in favorable toxicity profiles and high excellent to good cosmesis rates. Higher BMI was associated with moist desquamation, but prone positioning removed BMI and breast size as factors for poorer cosmetic outcomes. This series adds to the growing literature demonstrating that prone WBI may be advantageous in select patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。