Quality Assessment of Stereotactic Radiosurgery of a Melanoma Brain Metastases Model Using a Mouselike Phantom and the Small Animal Radiation Research Platform

利用小鼠模型和小动物放射研究平台对黑色素瘤脑转移模型进行立体定向放射外科手术质量评估

阅读:2

Abstract

PURPOSE: To establish a novel preclinical model for stereotactic radiosurgery (SRS) with combined mouselike phantom quality assurance in the setting of brain metastases. METHODS AND MATERIALS: C57B6 mice underwent intracranial injection of B16-F10 melanoma cells. T1-weighted postcontrast magnetic resonance imaging (MRI) was performed on day 11 after injection. The MRI images were fused with cone beam computed tomography (CBCT) images using the Small Animal Radiation Research Platform (SARRP). The gross tumor volume (GTV) was contoured using the MRI. A single sagittal arc using the 3 × 3 mm(2) collimator was used to deliver 18 Gy prescribed to the isocenter. MRI was performed 7 days after radiation treatment, and the dose delivered to the mice was confirmed using 2 mouselike anthropomorphic phantoms: 1 in the axial orientation and the other in the sagittal orientation. The SARRP output was measured using a PTW Farmer type ionization chamber as per the American Association of Physicists in Medicine Task Group report 61, and the H-D curve was generated up to a maximum dose of 30 Gy. Irradiated films were analyzed based on optical density distribution and H-D curve. RESULTS: The tumor volume on day 11, before intervention, was 2.48 ± 1.37 mm(3) in the no-SRS arm versus 3.75 ± 1.19 mm(3) in the SRS arm (NS). In the SRS arm, GTV maximum dose (Dmax) and mean dose were 2048 ± 207 and 1785 ± 14 cGy. Using the mouselike phantoms, the radiochromic film showed close precision in comparison with projected isodose lines, with a Dmax of 1903.4 and 1972.7 cGy, the axial and sagittal phantoms, respectively. Tumor volume 7 days after treatment was 7.34 ± 8.24 mm(3) in the SRS arm and 60.20 ± 40.4 mm(3) in the no-SRS arm (P=.009). No mice in the control group survived more than 22 days after implantation, with a median overall survival (mOS) of 19 days; mOS was not reached in the SRS group, with 1 death noted. CONCLUSIONS: Single-fraction SRS of 18 Gy delivered in a single arc can be delivered accurately with MRI T1-weighted postcontrast-based treatment planning. The mouse like phantom allows for verification of dose delivery and accuracy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。