Investigation of relative humidity distribution and its impact on disinfection using a combination of robotic fogger and hydrogen peroxide

研究相对湿度分布及其对采用机器人雾化器和过氧化氢联合消毒的影响

阅读:1

Abstract

BACKGROUND: Relative humidity is a key factor in the disinfection process. AIM: To examine the distribution of relative humidity, and the time required to reach its mean value in the target area when using a robotic fogger with 7.4% hydrogen peroxide. METHODS: The study evaluated the device in both stationary and mobile operation modes. In each mode, relative humidity sensors, along with chemical, biological, and enzyme indicators, were employed to assess the disinfection's effectiveness and consistency. RESULTS: The device dispersed disinfectant at a rate of 30 mL/min over 45 min in both modes. A shorter time to reach the mean relative humidity is desirable for effective disinfection. It was observed that the mobile mode reached the mean relative humidity 50% faster, maintained this level for an additional 30 min, and achieved an 11% higher relative humidity compared to the stationary mode. CONCLUSION: These advancements could assist pharmaceutical manufacturing and healthcare facilities in minimizing downtime during periodic disinfection.