Modified Technique of Setting Capsulotomy Thickness in Reducing Capsulotomy-Related Complications During Femtosecond Laser-Assisted Cataract Surgery: A Prospective, Comparative Cohort Study

飞秒激光辅助白内障手术中调整囊膜切开厚度以减少囊膜切开相关并发症的改良技术:一项前瞻性比较队列研究

阅读:1

Abstract

INTRODUCTION: Although uncommon, incomplete capsulotomy, anterior capsule tags and anterior capsule tears are still encountered during femtosecond laser-assisted cataract surgery (FLACS), resulting in surgical complications. This highlights the need to improve femtosecond laser-assisted capsulotomy technique to reduce capsulotomy-related complications. Therefore, the purpose of this study was to investigate the efficacy of a newly developed, modified technique of setting capsulotomy irradiation thickness in lowering the incidence of capsulotomy-related complications in FLACS. METHODS: This open-label prospective, comparative cohort study included 440 eyes (220 patients) treated with FLACS using the LenSx laser system (Alcon Laboratories, Inc. Fort Worth, TX, USA). Varying capsulotomy irradiation thicknesses were applied in each eye of the same patient. In Group 1, capsulotomy irradiation thickness was set between the upper edge of the highest point of the anterior capsule and the lower edge of the lowest point of the anterior capsule (modified technique). In Group 2, this was set between the center of the highest point of the anterior capsule and the center of the lowest part of the anterior capsule (conventional technique). Incidence rates of incomplete capsulotomy, anterior capsule tags and tears, and posterior capsule tears were compared. RESULTS: Preoperative baseline characteristics showed no significant differences. Mean total of the irradiation thicknesses was 877.1 ± 81.9 µm in Group 1 and 808.9 ± 80.0 in Group 2, with a statistically significant difference (P < 0.001). Incidences of incomplete capsulotomy were 1.8% and 7.7%, anterior capsule tags were 2.3% and 8.6%, and anterior capsule tears were 0% and 3.2% in Groups 1 and 2, respectively. These differences were statistically significant (P = 0.006, 0.005, and 0.015, respectively). No posterior capsule tears were reported in either group. CONCLUSION: The modified technique for capsulotomy in FLACS may significantly reduce the occurrence of capsulotomy-related complications, maximizing the benefits of FLACS.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。