Improving automatic cerebral 3D-2D CTA-DSA registration

改进自动脑部3D-2D CTA-DSA配准

阅读:1

Abstract

PURPOSE: Stroke remains a leading cause of morbidity and mortality worldwide, despite advances in treatment modalities. Endovascular thrombectomy (EVT), a revolutionary intervention for ischemic stroke, is limited by its reliance on 2D fluoroscopic imaging, which lacks depth and comprehensive vascular detail. We propose a novel AI-driven pipeline for 3D CTA to 2D DSA cross-modality registration, termed DeepIterReg. METHODS: The proposed pipeline integrates neural network-based initialization with iterative optimization to align pre-intervention and peri-intervention data. Our approach addresses the challenges of cross-modality alignment, particularly in scenarios involving limited shared vascular structures, by leveraging synthetic data, vein-centric anchoring, and differentiable rendering techniques. RESULTS: We assess the efficacy of DeepIterReg through quantitative analysis of capture ranges and registration accuracy. Results show that our method can accurately register 70% of a test set of 20 patients and can improve capture ranges when performing an initial pose estimation using a convolutional neural network. CONCLUSIONS: DeepIterReg demonstrates promising performance for 3D-to-2D stroke intervention image registration, potentially aiding clinicians by improving spatial understanding during EVT and reducing dependence on manual adjustments.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。