Heparin-coated vs. Non-coated Cardiopulmonary Bypass Circuits: Comparing Immediate Results with Different Target Activated Clotting Time

肝素涂层与非涂层体外循环回路:比较不同目标活化凝血时间下的即时结果

阅读:1

Abstract

OBJECTIVE: To compare immediate postoperative results in patients receiving heparin-albumin-coated and non-coated circuits. METHODS: A total of 241 patients undergoing on-pump cardiac surgery were divided into two groups: those receiving heparin-coated circuits (Bioline®, Maquet Cardiopulmonary AG., Hirrlingen, Germany) and those receiving non-coated circuits (Maquet Cardiopulmonary AG., Hirrlingen, Germany). RESULTS: Activated clotting times (ACT) during cardiopulmonary bypass (CPB) were significantly shorter in the heparin-albumin-coated group than in the non-coated group (355.64±34.12 vs. 560.38±90.20, respectively, P=0.001). In-hospital mortality and postoperative stroke rates and lengths of intensive care unit stay were similar between the groups; in contrast, in the heparin-albumin-coated group, patients had significantly better outcomes for hospital stay, drainage, and need for erythrocyte transfusion. CONCLUSION: Heparin-coated circuits and reduced level of systemic heparinization with 300 seconds of target ACT level in cardiac surgery under CPB are safe and result in a very satisfactory clinical course.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。