Test-Retest Reliability of Two Consecutive Mean Sleep Latency Tests in Patients with Hypersomnia

嗜睡症患者两次连续平均睡眠潜伏期测试的重测信度

阅读:1

Abstract

Reliability of mean sleep latency testing (MSLT) over consecutive days in patients with hypersomnia is unknown. We reviewed MSLTs of patients with hypersomnia without cataplexy who underwent our two consecutive MSLT protocol (N=29). Average MSLs were 10.9 and 10.9 minutes for days 1 and 2, respectively. Agreement for pathological hypersomnia (defined as MSL≤8 minutes) between MSLT days showed k=0.85 for all (N=29) and k=0.76 for those without sleep apnea (N=20). In patients with subjective complaints of hypersomnia, a single MSLT is sufficient (vs. addition of 2(nd) day MSLT) in the setting of carefully implemented protocol controlling for potential confounding variables.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。