[The intra-observer variability of volumetric measurement of pulmonary nodules: comparison of two-dimensional and three-dimensional method]

[肺结节体积测量的观察者内变异性:二维法与三维法的比较]

阅读:1

Abstract

BACKGROUND AND OBJECTIVE: Software oriented three-dimensional (3D) volumetric measurement of pulmonary nodules has been feasible in the follow-up of indeterminate pulmonary nodules, however, its value need a further validation. The purpose of this study is to retrospectively analyze the chest CT data of patients with pulmonary nodules to compare the intra-observer variability of 3D and two-dimensional (2D) volumetric measurement. METHODS: Eighty-six pulmonary nodules in chest CT scans of 79 subjects were retrospectively analyzed. One radiologist measured the nodules twice with a 7 days interval using 2D and 3D methods respectively. The maximal diameter (X), the perpendicular diameter (Y) on maximal cross sectional area of the nodule and the caudo-cranial diameter (Z) were measured and the volume was calculated by two models: spherical and elliptical model. The 3D measurements were acquired with semi-automated software with manual adjustment on unsatisfied nodule segmentation. Logistic regression analysis was performed to evaluate the effect of nodule location and morphology on 3D nodule segmentation. ANOVA and correlation test were used to evaluate the difference among three methods. Bland-Altman method was applied to quantify the intra-observer variability. RESULTS: Software achieved satisfied segmentation for 86.4% nodules. The irregular and juxtavacular nodules have significantly high odds rations (OR) of unsatisfied segmentation as 4.0, 4.5, respectively. The volume measured by three method was significantly different (F=6.5, P=0.012), while the repeated measurements did not led to significant difference (F=1.813, P=0.182). The Spearman correlation efficient between 3D volume and 2D volume with sphere and ellipsoid model was 0.97, 0.88. The 95% limits of agreement of RD between two repeated measurements were -14%-11.6%, -37.7%-39.9% and -39.8%-45.8% for 3D, 2D with elliptical model and spherical model, respectively. CONCLUSIONS: The 3D volume measurement of pulmonary nodules is more repeatable than 2D volume measurement. Unsatisfied segmentation can occurred on a small number of nodules, especially for irregular and juxtavascular nodules. For these nodules, the measurement of 3D diameters is recommended.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。