BACKGROUND: To compare image quality, metal artifacts, and diagnostic confidence of conventional computed tomography (CT) images of unilateral total hip arthroplasty patients (THA) with deep learning-based metal artifact reduction (DL-MAR) to conventional CT and 130-keV monoenergetic images with and without orthopedic metal artifact reduction (O-MAR). METHODS: Conventional CT and 130-keV monoenergetic images with and without O-MAR and DL-MAR images of 28 unilateral THA patients were reconstructed. Image quality, metal artifacts, and diagnostic confidence in bone, pelvic organs, and soft tissue adjacent to the prosthesis were jointly scored by two experienced musculoskeletal radiologists. Contrast-to-noise ratios (CNR) between bladder and fat and muscle and fat were measured. Wilcoxon signed-rank tests with Holm-Bonferroni correction were used. RESULTS: Significantly higher image quality, higher diagnostic confidence, and less severe metal artifacts were observed on DL-MAR and images with O-MAR compared to images without O-MAR (p < 0.001 for all comparisons). Higher image quality, higher diagnostic confidence for bone and soft tissue adjacent to the prosthesis, and less severe metal artifacts were observed on DL-MAR when compared to conventional images and 130-keV monoenergetic images with O-MAR (p ≤ 0.014). CNRs were higher for DL-MAR and images with O-MAR compared to images without O-MAR (p < 0.001). Higher CNRs were observed on DL-MAR images compared to conventional images and 130-keV monoenergetic images with O-MAR (p ≤ 0.010). CONCLUSIONS: DL-MAR showed higher image quality, diagnostic confidence, and superior metal artifact reduction compared to conventional CT images and 130-keV monoenergetic images with and without O-MAR in unilateral THA patients. RELEVANCE STATEMENT: DL-MAR resulted into improved image quality, stronger reduction of metal artifacts, and improved diagnostic confidence compared to conventional and virtual monoenergetic images with and without metal artifact reduction, bringing DL-based metal artifact reduction closer to clinical application. KEY POINTS: • Metal artifacts introduced by total hip arthroplasty hamper radiologic assessment on CT. • A deep-learning algorithm (DL-MAR) was compared to dual-layer CT images with O-MAR. • DL-MAR showed best image quality and diagnostic confidence. • Highest contrast-to-noise ratios were observed on the DL-MAR images.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。